Related Experiment Video
Updated: Jul 5, 2026

A Standardized Method for Measurement of Elbow Kinesthesia
Published on: October 10, 2020
Estimation of forces exerted by the fingers using standardised surface electromyography from the forearm
Angela DiDomenico1, Maury A Nussbaum
1Liberty Mutual Research Institute for Safety, Hopkinton, MA 01748, USA. angela.didomenico@libertymutual.com
Abstract:
Determination and integration of human force capabilities and requirements is an essential component of ergonomic evaluation. With regard to hand-intensive tasks, direct force measurements can be cumbersome and intrusive. Here, the use of surface electromyography (EMG) was evaluated. EMG was obtained from three standardised electrode sites on the forearms of 30 individuals. Linear regression models were generated to estimate finger force levels from normalised electromyographic measures, while forces were generated in several finger couplings. The results suggest that standardised procedures for obtaining electromyographic data and simple linear models can be used to accurately estimate finger forces during a variety of finger exertions in fixed postures, although the level of accuracy depends on the type of model. Such models begin to overcome the limitations of direct finger strength measurements of individuals.