Near-Infrared Spectroscopy During Reactive Hyperemia for the Assessment of Lower Limb Vascular Function
Published on: March 22, 2024
A method to calculate arterial and venous saturation from near infrared spectroscopy (NIRS)
Jan Menssen1, Willy Colier, Jeroen Hopman
1Dept. of Pediatrics, Radboud University Nijmegen Medical Centre, Nijmegen, The Netherlands. j.menssen@cukz.umcn.nl
Abstract:
For adequate development and functioning of the neonatal brain, sufficient oxygen (O2) should be available. With a fast sampling (f(s) > 50 Hz) continuous wave NIRS device, arterial (SaO2) and venous (SvO2) saturation can be measured using the physiological fluctuations in the oxyhemoglobin (O2Hb) and total hemoglobin (tHb) concentrations due to heart action and respiration. Before using this technique in a neonatal setting, the method was verified on adult volunteers (n=7) by decreasing inspired oxygen down to an arterial saturation of 70% using a pulse oximeter as reference. NIRS optodes were placed on the left forehead; the pulse oximeter sensor was placed on the right forehead. The experiments were repeated with different optode spacings. SaO2 and SvO2 were determined using the ratio between the O2Hb and tHb value in the amplitude spectrum at the heart rate and respiration rate, respectively. A good agreement between calculated SaO2 and reference SaO2 from pulse oximetry was found (bias range -3.5% to 5.2%, SD of the residuals 1.3% to 3.5%). Optode spacing of 15 mm yielded a negative bias compared to optode spacing of 45 mm. It was not always possible to calculate SvO2 because the respiration peak could not always be detected.
More Related Videos
07:27How to Administer Near-Infrared Spectroscopy in Critically ill Neonates, Infants, and Children
Published on: August 19, 2020
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
The ATR process begins by directing a beam...
Assessment of blood pressure in brachial artery(two-step method)