Related Experiment Video
Updated: Jun 25, 2026

Cerebral Blood Oxygenation Measurement Based on Oxygen-dependent Quenching of Phosphorescence
Published on: May 4, 2011
Non-invasive measurement of the superficial cortical oxygen partial pressure
Chris Woertgen1, Jan Warnat, Alexander Brawanski
1Dept. of Neurosurgery, University of Regensburg, 93042 Regensburg, Germany.
Abstract:
We present a non invasive fluorescein based method to measure and visualise the partial oxygen pressure of the rat cortex in a 2D picture. We studied 10 Wistar rats. A trepanation was done over the hemisphere and the dura was opened. A PMMA cylinder with a calibrated optical membrane was fixed over the surface of the brain. The CCD camera with the light source is placed over the cylinder. This allows the generation of two-dimensional maps of the pO2 pressure. Using the white light picture we defined regions of interest (ROI) in an artery, vein, parenchyma and an overall ROI. For every ROI a mean emission value was calculated. We increased, stepwise, the FiO2 from 30% up to 100%. Thereafter we established ventilation with an FiO2 of 30% and induced a stepwise hypo- and hyperventilation. The ROI's showed significantly different pO2 values. The apO2 showed a good correlation to the pO2 in the ROIs. This new set up seems to give reliable absolute pO2 values of the brain surface. This method seems to be able for the first time to give a non invasive pO2 map of the brain surface reflecting oxygenation and ventilation effects.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
12:03Detection of Microregional Hypoxia in Mouse Cerebral Cortex by Two-photon Imaging of Endogenous NADH Fluorescence
Published on: February 21, 2012
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.