Photoacoustic image reconstruction from few-detector and limited-angle data

Lei Yao1, Huabei Jiang

  • 1Department of Biomedical Engineering, University of Florida, Gainesville, FL 32611, USA.

Biomedical Optics Express
|October 13, 2011
PubMed
Summary

This study introduces a total-variation-minimization enhanced algorithm for photoacoustic tomography (PAT) imaging. The new method significantly improves image quality, even with limited measurement data.

Related Concept Videos

The Number e as a Limit01:29

The Number e as a Limit

The number e is a fundamental constant in calculus, playing a central role in describing continuous change, particularly exponential growth. It is most naturally defined through its relationship with the natural logarithm, which is the inverse of the exponential function with base e. This relationship allows e to be characterized using basic principles of differentiation rather than as an arbitrary numerical constant.A key property of the natural logarithm function, ln x, is that its derivative...
85
Limiting Reactant02:27

Limiting Reactant

The relative amounts of reactants and products represented in a balanced chemical equation are often referred to as stoichiometric amounts. However, in reality, the reactants are not always present in the stoichiometric amounts indicated by the balanced equation.
70.0K
Contact Angle01:13

Contact Angle

When a solid is dipped inside a liquid, the liquid surface becomes curved near the contact. For some solid–liquid interfaces, the liquid is pulled up along the solid, while for others, the liquid surface is convex or depressed near the solid surface. This phenomenon can be explained using the concept of cohesive and adhesive forces.
The adhesive force is the molecular force between molecules of different materials, that is, between the molecules of the solid and the liquid. The cohesive...
19.5K
Gas Chromatography: Types of Detectors-I01:21

Gas Chromatography: Types of Detectors-I

There are different types of detectors used in gas chromatography, each with its own specific properties that make it suitable for detecting certain types of analytes. The most commonly used detectors in GC are thermal conductivity detector (TCD), flame ionization detector (FID), and electron capture detector (ECD).
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
1.6K
Gas Chromatography: Overview of Detectors01:13

Gas Chromatography: Overview of Detectors

Detectors in gas chromatography (GC) help identify and quantify the components of a mixture by translating chemical properties into measurable signals, which are displayed on a chromatogram. Detectors can be categorized into two main types: destructive and non-destructive.
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
2.0K
Gas Chromatography: Types of Detectors-II01:19

Gas Chromatography: Types of Detectors-II

In gas chromatography, different detectors are employed to meet specific analytical needs. These detectors are often categorized based on their detection mechanisms and the types of compounds they are best suited to analyze. Thermal Conductivity Detectors (TCD), Flame Ionization Detectors (FID), and Electron Capture Detectors (ECD) represent common categories, each with unique operating principles and applications. However, beyond these, several other detectors are designed for more specialized...
1.2K