Medical-grade Sterilizable Target for Fluid-immersed Fetoscope Optical Distortion Calibration
Published on: February 23, 2017
Cross-diffractive optical elements for wide angle geometric camera calibration.
Simon Thibault1, Aymen Arfaoui, Pierre Desaulniers
1Center for Optics, Photonics and Lasers, Laval University, Québec, QC, Canada. simon.thibault@phy.ulaval.ca
Optics Letters
|December 20, 2011
Summary
This study introduces a cost-effective method for camera calibration using two large diffractive optical elements (DOEs). This technique expands the calibration field of view for wide-angle aerial cameras, overcoming previous limitations.
Area of Science:
- Optics
- Photogrammetry
- Optical Engineering
Background:
- Diffractive optical elements (DOEs) enable camera calibration via 2D diffraction grids.
- Current DOE fabrication limits accuracy, functionality, and camera/angle scope.
Purpose of the Study:
- To present a low-cost solution for enhancing camera calibration using commercially available DOEs.
- To expand the calibration field of view for wide-angle aerial cameras.
Main Methods:
- Utilized two large, commercially available, crossed phase DOEs generating 15x15 dot grids.
- Employed primary and secondary diffractive orders as calibration targets.
- Developed a technique to overcome DOE fabrication limitations.
Main Results:
- Demonstrated a valuable calibration tool for wide-angle aerial cameras.
- Successfully expanded the calibration field of view beyond primary orders.
- Achieved accurate camera calibration using secondary diffractive orders.
Conclusions:
- The proposed method offers a cost-effective approach to camera calibration.
- Leveraging secondary diffractive orders enhances calibration capabilities.
- This technique overcomes limitations of traditional DOE fabrication for photogrammetry.
Related Concept Videos
Glassware Calibration
Accurate calibration of glassware, such as volumetric flasks, pipettes, and burettes, is essential to ensure accurate measurements in the analytical laboratory. Calibration helps maintain consistency across measurements and prevents errors arising from inaccurate volumes.
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Phase Contrast and Differential Interference Contrast Microscopy
Phase-Contrast Microscopes
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...