An evaluation of two calibration procedures using thermal desorption-gas chromatography in the analysis of odorous volatile compounds
Related Experiment Video
Updated: May 22, 2026

Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
1Department of Environment and Energy, Sejong University, Seoul, 143-747 Korea.
Abstract:
In this study, the relative performance of gas chromatography (GC) was investigated with respect to the differences in two types of calibration approaches with a thermal desorption (TD) method: the fixed standard concentration approach (FSC: the comparison of different sample volumes for a given standard) was compared with the fixed standard volume approach (FSV: the comparison of different concentration standards at a fixed loading volume). Gaseous working standards of seven odorants, including methyl ethyl ketone (MEK), butyl acetate, methyl isobutyl ketone, isobutyl alcohol, toluene, xylene, and a reference component, benzene, were prepared at four concentration levels (10-100 ppb). They were then analyzed by controlling the TD-loading volumes at six levels (40-1200 mL). The results derived by these contrasting calibration approaches showed moderate changes in the GC sensitivity, either with an increasing concentration (i.e., FSC), or with an increasing sample loading volume (i.e., FSV). Despite an eccentric trend of MEK, the TD-based analysis was fairly predictable and can be recommended for the analysis of the selected odorants.
More Related Videos
05:22Rapid Collection of Floral Fragrance Volatiles using a Headspace Volatile Collection Technique for GC-MS Thermal Desorption Sampling
Published on: December 10, 2019
06:51Quantitative Analysis by Thermogravimetry-Mass Spectrum Analysis for Reactions with Evolved Gases
Published on: October 29, 2018
Related Concept Videos
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Types of Detectors-II
Volatilization
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...