A sub-mW fully-integrated pulse oximeter front-end
Konstantinos N Glaros1, Emmanuel M Drakakis
1Department of Bioengineering, Imperial College London, London SW7 2AZ, UK. glarosk@gmail.com
Abstract:
This paper presents the implementation of the first fully integrated pulse oximeter front-end with a power consumption lower than 1 mW. This is enabled by system- and block-level noise optimisation, also detailed in the manuscript. The proposed design features an analogue feedback loop that enables fast and accurate regulation of the detected photocurrent level and a serial-to-parallel interface allowing for extensive programmability of several operation parameters. The front-end was fabricated in the AMS 0.35 μm technology and occupies an area of 1.35 mm(2). Extensive measured results, both electrical and physiological from human subjects are reported, demonstrating an estimated SNR of 39 dB and ability to detect 2% changes in SpO2, similar to commercial pulse oximeters. This is despite the constrained power consumption which amounts to 0.31 mW for the LEDs and 0.53 mW for the rest of the front-end from a 3.3 V supply. Statistical results from 20 chips verify good matching across the Red and Infrared channels of the front-end and the accurate operation of the proposed analogue feedback loop.
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...