Iron mapping using the temperature dependency of the magnetic susceptibility
Christoph Birkl1, Christian Langkammer, Heinz Krenn
1Department of Neurology, Medical University of Graz, Austria.
Purpose:
The assessment of iron content in brain white matter (WM) is of high importance for studying neurodegenerative diseases. While R2 * mapping and quantitative susceptibility mapping is suitable for iron mapping in gray matter, iron mapping in WM still remains an unsolved problem. We propose a new approach for iron mapping, independent of diamagnetic contributions of myelin by assessing the temperature dependency of the paramagnetic susceptibility.
Theory And Methods:
We used unfixed human brain slices for relaxometry and calculated R2 ' as a measure for microscopic susceptibility variations at several temperatures (4°C-37°C) at 3 Tesla. The temperature coefficient of R2 ' (TcR2p) was calculated by linear regression and related to the iron concentration found by subsequent superconducting quantum interference device (SQUID) magnetometry and by inductively coupled plasma mass spectrometry.
Results:
In line with SQUID measurements, R2 ' mapping showed a linear temperature dependency of the bulk susceptibility with the highest slope in gray matter. Even in WM, TcR2p yielded a high linear correlation with the absolute iron concentration.
Conclusion:
According to Curie's law, only paramagnetic matter exhibits a temperature dependency while the diamagnetism shows no effect. We have demonstrated that the temperature coefficient (TcR2p) can be used as a measure of the paramagnetic susceptibility despite of an unknown diamagnetic background.
More Related Videos
08:52Near-Infrared Temperature Measurement Technique for Water Surrounding an Induction-heated Small Magnetic Sphere
Published on: April 30, 2018
08:55Methods of Ex Situ and In Situ Investigations of Structural Transformations: The Case of Crystallization of Metallic Glasses
Published on: June 7, 2018
Related Concept Videos
Magnetic Susceptibility and Permeability
When diamagnetic materials are placed under an external magnetic field, the moments opposite to the field are induced. Hence, the susceptibility for diamagnets has a minimal negative value of 10-5–10-6. Since...
Ferromagnetism
Magnetic Resonance Imaging
Diamagnetism
Diamagnetism was discovered by Anton Brugmans in 1778 when he observed that bismuth gets repelled by magnetic fields, thus theorizing that diamagnets get repelled by magnets....
Paramagnetism
Other Unique Bacteria