Evaluation of Capnography Sampling Line Compatibility and Accuracy when Used with a Portable Capnography Monitor
Published on: September 29, 2020
Variability of Transcutaneous Oxygen and Carbon Dioxide Pressure Measurements Associated with Sensor Location
K Górska1, P Korczyński, M Maskey-Warzęchowska
1Department of Internal Medicine, Pneumology and Allergology, Medical University of Warsaw, 1a Banacha St., Warsaw, Poland, drkpgorska@gmail.com.
Abstract:
Transcutaneous measurement of oxygen and carbon dioxide pressure (PtcO2 and PtcCO2) is useful in gas exchange monitoring. However, the relationship between PtcO2, pulse oximetry (SaO2) and arterial blood gases (ABG) is unclear. The aim of the present study was to compare PtcO2 and PtcCO2 with SaO2 and ABG, to evaluate the effect of sensor location on the results and stability of PtcO2 and PtcCO2, and to assess the impact of body composition on PtcO2 and PtcCO2. PtcO2 and PtcCO2 were measured in 20 healthy volunteers at three locations: right second intercostal space, lateral surface of the abdomen, and the inner surface of the left arm. The results were recorded 10, 15, and 20 min after sensor fixation and compared with SaO2 and ABG measured 20 min after electrode placement on the chest. Body composition was evaluated by bioimpedance. The findings were that PtcO2 was stable on the chest; but on the arm and abdomen it increased and reached maximum at 20 min. Transcutaneous PCO2 stabilized at 10 min in all the three locations. No significant correlations between PtcO2 and SaO2 or PaO2 were found. Transcutaneous PCO2 correlated with PaCO2. Both PtcO2 and PtcCO2 were not influenced by body composition. We conclude that the value of PtcO2 in monitoring of blood oxygenation was not unequivocally confirmed; PtcCO2 reliably reflects PaCO2, irrespective of sensor location. Body composition does not affect PtcO2 and PtcCO2.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
08:25Combining Volumetric Capnography And Barometric Plethysmography To Measure The Lung Structure-function Relationship
Published on: January 8, 2019
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Measurement of Fluid Pressure
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...
Measurement of Blood Pressure
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...