Related Experiment Videos

Immediate Closures and Violations Identified During Routine Inspections of Public Aquatic Facilities - Network for

Michele C Hlavsa1, Taryn R Gerth, Sarah A Collier

  • 1Division of Foodborne, Waterborne, and Environmental Diseases, National Center for Emerging and Zoonotic Infections Diseases, CDC.

Morbidity and Mortality Weekly Report. Surveillance Summaries (Washington, D.C. : 2002)
|May 21, 2016
PubMed
Abstract

Related Concept Videos

Quality of Water01:19

Quality of Water

In concrete preparation, the quality of water is paramount as it affects the strength and durability of the concrete. Potable water is usually preferred; however, it must not have excessive sodium or potassium to prevent compromising the concrete's integrity. Water quality is typically evaluated based on impurities such as dissolved solids, chlorides, and sulfates, and its pH value is ideally between 6 and 8. Even slightly acidic natural water may be acceptable unless it contains harmful...
644
Testing Water Quality01:14

Testing Water Quality

When the quality of water for concrete preparation is uncertain, its impact on the setting time of cement and compressive strength of mortar is assessed by comparison with de-ionized or distilled water benchmarks. American Society for Testing and Materials (ASTM) C1602 requires the setting times to be within 90 minutes of the control, British Standard (BS) 3146:1980 allows a 30-minute variance in the initial setting, while British Standards European Norm (BS EN) 1008 specifies initial setting...
446
Underflow Gates01:30

Underflow Gates

Underflow gates are vital for controlling water flow in irrigation canals. The three main types of underflow gates — vertical, radial, and drum gates — serve different purposes while ensuring effective flow management. Vertical gates move up and down, generating a free-flowing water jet; radial gates pivot to regulate the flow; and drum gates rotate for precise adjustments. The flow through these gates is influenced by downstream conditions, resulting in free or drowned outflow.Free and...
512
Types of Reports II: Incident or Occurrence Report01:21

Types of Reports II: Incident or Occurrence Report

An Incident or Occurrence Report in a healthcare setting is a crucial document used to record any unexpected occurrence that may or may not have affected a patient, employee, or visitor. Such reports are critical to improving patient safety and include all details leading up to and including the event.
Purposes:
In the healthcare industry, reports play a crucial role in documenting incidents within an agency. The primary objective of these reports is to ensure patient safety, uphold the...
1.3K
Deleterious Substances in Aggregate01:25

Deleterious Substances in Aggregate

Deleterious substances in aggregates can be detrimental to the quality and durability of concrete. These substances include organic impurities like loam, which interfere with cement hydration and are usually present in the sand. These prevent a good bond between aggregate and cement paste. Organic impurities can be detected using the colorimetric test, where the darkness of a solution after agitation indicates the level of organic content.
Another type of impurity is clay and fine material that...
659
Cavity Drainage and Flashings in Masonry walls01:20

Cavity Drainage and Flashings in Masonry walls

Typically, a cavity wall consists of two wythes separated by a gap of at least 2 inches, which may contain insulation while still maintaining a minimum clear space of 1 inch to facilitate adequate drainage. Advanced methods like the insertion of a continuous drainage mat can further reduce this space while ensuring effective moisture expulsion.
Weep holes, strategically placed at the base of the cavity, are critical for draining accumulated water. These openings are created by leaving head...
570