Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

X-ray Imaging01:24

X-ray Imaging

10.9K
German physicist Wilhelm Röntgen (1845–1923) was experimenting with electrical current when he discovered that a mysterious and invisible "ray" would pass through his flesh but leave an outline of his bones on a screen coated with a metal compound. In 1895, Röntgen made the first durable record of the internal parts of a living human: an "X-ray" image (as it came to be called) of his wife’s hand. Scientists worldwide quickly began their own experiments with...
10.9K
Imaging Studies II: Positron Emission Tomography and Scintigraphy01:25

Imaging Studies II: Positron Emission Tomography and Scintigraphy

705
Positron Emission Tomography (PET) is a medical imaging technique that provides crucial insights into the body's physiological functions at a molecular level. It is an indispensable resource for diagnosing, staging, and monitoring various illnesses, notably cancer, neurological disorders, and cardiovascular conditions.
Fundamental Principles of PET
705
Positron Emission Tomography01:29

Positron Emission Tomography

7.9K
Positron emission tomography (PET) is a medical imaging technique involving radiopharmaceuticals — substances that emit short-lived radiation. Although the first PET scanner was introduced in 1961, it took 15 more years before radiopharmaceuticals were combined with the technique and revolutionized its potential.
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
7.9K
Radiological Investigation I: X-ray and CT01:30

Radiological Investigation I: X-ray and CT

1.5K
Radiological investigations, including X-rays and computed tomography (CT) scans, are critical for diagnosing and evaluating various medical conditions. These imaging techniques provide valuable insights into the body's internal structures, aiding in the detection of abnormalities, assessment of disease progression, and development of treatment strategies. This article delves into two primary radiological investigations, chest X-rays and CT scans, outlining their purpose, procedures, and...
1.5K
Scanning Electron Microscopy01:07

Scanning Electron Microscopy

5.8K
A scanning electron microscope (SEM) is used to study the surface features of a sample by using an electron beam that scans the sample surface in a two-dimensional manner. Typically, areas between ~1 centimeter to 5 micrometers in width can be imaged. SEM can be used to image bacteria, viruses, tissues as well as larger samples like insects. Conventional SEM gives a magnification ranging from 20X to 30,000X and spatial resolution of 50 to 100 nanometers.
Fundamental Principles
Accelerated...
5.8K
Electron Microscope Tomography and Single-particle Reconstruction01:07

Electron Microscope Tomography and Single-particle Reconstruction

3.0K
Transmission electron microscopy (TEM) can be used to determine the 3D structure of biological samples with the help of techniques such as electron microscope tomography and single-particle reconstruction. While single-particle reconstruction can examine macromolecules and macromolecular complexes in vitro conditions only, tomography permits the study of cell components or small cells in vivo.
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
3.0K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Controlled intramural fluid injection to quantify propensity to thoracic aortic dissection.

Research square·2026
Same author

On optimisation of Paganin's method for propagation-based X-ray phase-contrast imaging and tomography.

Journal of microscopy·2026
Same author

Criteria for selecting the Paganin-filter reconstruction parameter in X-ray phase-contrast tomography.

Journal of synchrotron radiation·2026
Same author

Detect and Trace: An Australian Field Trial Using Machine-Learning Tools to Combat Illegal Wildlife Trade.

Animals : an open access journal from MDPI·2026
Same author

Demonstration of a family of X-ray dark-field retrieval approaches on a common set of samples.

Journal of synchrotron radiation·2026
Same author

Active wave-particle clusters.

Physical review. E·2026
Same journal

Erratum: Bacterial Turbulence at Compressible Fluid Interfaces [Phys. Rev. Lett. 136, 138301 (2026)].

Physical review letters·2026
Same journal

Unveiling Light-Quark Yukawa Flavor Structure via Dihadron Fragmentation at Lepton Colliders.

Physical review letters·2026
Same journal

Adaptable Route to Fast Coherent State Transport via Bang-Bang-Bang Protocols.

Physical review letters·2026
Same journal

Topological Transition and Emergence of Elasticity of Dislocation in Skyrmion Lattice: Beyond Kittel's Magnetic-Polar Analogy.

Physical review letters·2026
Same journal

Pound-Drever-Hall Method for Superconducting-Qubit Readout.

Physical review letters·2026
Same journal

Coupling a ^{73}Ge Nuclear Spin to an Electrostatically Defined Quantum Dot in Silicon.

Physical review letters·2026
See all related articles

Related Experiment Video

Updated: Mar 14, 2026

High Spatial Resolution Chemical Imaging of Implant-Associated Infections with X-ray Excited Luminescence Chemical Imaging Through Tissue
07:48

High Spatial Resolution Chemical Imaging of Implant-Associated Infections with X-ray Excited Luminescence Chemical Imaging Through Tissue

Published on: September 30, 2022

1.7K

Experimental X-Ray Ghost Imaging.

Daniele Pelliccia1,2,3, Alexander Rack4, Mario Scheel5

  • 1School of Science, RMIT University, Victoria 3001, Australia.

Physical Review Letters
|September 24, 2016
PubMed
Summary
This summary is machine-generated.

Ghost imaging was experimentally demonstrated using hard X-rays. This technique uses correlated X-ray beams to image samples, potentially reducing radiation damage in medical imaging and materials analysis.

More Related Videos

Author Spotlight: Using Hyperpolarized Xenon-129 MRI to Study Lung Diseases
09:55

Author Spotlight: Using Hyperpolarized Xenon-129 MRI to Study Lung Diseases

Published on: January 5, 2024

1.9K
Applying X-ray Imaging Crystal Spectroscopy for Use as a High Temperature Plasma Diagnostic
06:46

Applying X-ray Imaging Crystal Spectroscopy for Use as a High Temperature Plasma Diagnostic

Published on: August 25, 2016

11.8K

Related Experiment Videos

Last Updated: Mar 14, 2026

High Spatial Resolution Chemical Imaging of Implant-Associated Infections with X-ray Excited Luminescence Chemical Imaging Through Tissue
07:48

High Spatial Resolution Chemical Imaging of Implant-Associated Infections with X-ray Excited Luminescence Chemical Imaging Through Tissue

Published on: September 30, 2022

1.7K
Author Spotlight: Using Hyperpolarized Xenon-129 MRI to Study Lung Diseases
09:55

Author Spotlight: Using Hyperpolarized Xenon-129 MRI to Study Lung Diseases

Published on: January 5, 2024

1.9K
Applying X-ray Imaging Crystal Spectroscopy for Use as a High Temperature Plasma Diagnostic
06:46

Applying X-ray Imaging Crystal Spectroscopy for Use as a High Temperature Plasma Diagnostic

Published on: August 25, 2016

11.8K

Area of Science:

  • Physics
  • Optics
  • Materials Science

Background:

  • Ghost imaging is an advanced optical technique that allows image reconstruction from non-spatially-resolved measurements.
  • Previous ghost imaging experiments have been limited to lower energy photons, such as visible light or soft X-rays.

Purpose of the Study:

  • To demonstrate the feasibility of ghost imaging in the hard X-ray energy range.
  • To explore the potential applications of hard X-ray ghost imaging in fields like medical imaging and materials characterization.

Main Methods:

  • Utilized a synchrotron X-ray beam split by a thin crystal in Laue diffraction geometry.
  • Employed an ultrafast imaging camera to capture X-rays from isolated electron bunches.
  • Correlated the integrated transmitted intensity from a sample in one beam with the spatially resolved intensity in the second, empty beam.

Main Results:

  • Successfully achieved ghost imaging in the hard X-ray range.
  • Observed measurable speckle correlations between the two X-ray beams due to shot noise.
  • Retrieved the shadow of a sample by correlating intensity measurements between the beams.

Conclusions:

  • This work provides an experimental proof of principle for hard X-ray ghost imaging.
  • The technique holds promise for reducing radiation damage in medical imaging and enabling advanced non-destructive structural characterization with free electron lasers.