Gamma-ray CT from incomplete projections for two-phase pipe flow
1Beijing University of Civil Engineering and Architecture, Beijing, People's Republic of China.
The Review of Scientific Instruments
|March 3, 2017
Summary
A low-dose gamma-ray computed tomography (CT) system was developed for gas-liquid two-phase pipe flow measurement. The system successfully reconstructs images from incomplete projections, enabling effective flow monitoring.
Area of Science:
- Nuclear Engineering
- Imaging Science
- Fluid Dynamics
Background:
- Gas-liquid two-phase flow measurement is crucial for industrial processes.
- Traditional methods face limitations in accuracy and safety.
- Gamma-ray computed tomography (CT) offers a non-invasive alternative.
Purpose of the Study:
- To develop and evaluate a low-energy, low-dose gamma-ray CT system for two-phase pipe flow.
- To improve image reconstruction from incomplete projections.
- To optimize scanning parameters and reduce radiation dose.
Main Methods:
- Utilized a third-generation X-ray CT configuration with a 241Am source and CdZnTe detectors.
- Implemented an A-variable algebraic reconstruction technique (ART) for image reconstruction.
- Conducted static and dynamic experiments with full and partial scan data.
Main Results:
- Achieved a spatial image resolution of approximately 7 mm.
- Demonstrated successful image reconstruction from incomplete projections.
- Identified acceptable performance for flow rates < 0.04 m/s at imaging speeds < 33 frames/s.
Conclusions:
- The developed gamma-ray CT system is feasible for two-phase pipe flow measurement.
- Image reconstruction from incomplete projections is viable, reducing scanning time and dose.
- The system provides a promising tool for industrial flow monitoring and optimization.
Related Concept Videos
General Characteristics of Pipe Flow II
1.7K
When fluid enters a pipe, it first passes through the entrance region, where the velocity profile adjusts due to viscous effects. In this region, a boundary layer forms along the pipe walls and grows until it fully occupies the pipe's cross-section. Once the boundary layer merges, the flow becomes fully developed, with a steady velocity profile that remains consistent along the pipe's length.
The distance to reach a fully developed flow is called the entrance length and depends on the...
The distance to reach a fully developed flow is called the entrance length and depends on the...
1.7K
Computed Tomography
9.2K
Tomography refers to imaging by sections. Computed tomography (CT) is a non-invasive imaging technique that uses computers to analyze several cross-sectional X-rays to reveal minute details about structures in the body.
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
9.2K
General Characteristics of Pipe Flow I
1.8K
Pipe flow refers to the movement of fluids within fully enclosed conduits, typically cylindrical in shape, such as water pipes or hydraulic hoses. These conduits are designed to withstand high-pressure gradients that drive fluid movement, contrasting with open-channel flows, where gravity is the primary driving force. Rectangular conduits, like air conditioning and heating ducts, generally operate at lower pressures and are less suited for high-pressure applications.
The classification of fluid...
The classification of fluid...
1.8K
Imaging Studies II: Positron Emission Tomography and Scintigraphy
684
Positron Emission Tomography (PET) is a medical imaging technique that provides crucial insights into the body's physiological functions at a molecular level. It is an indispensable resource for diagnosing, staging, and monitoring various illnesses, notably cancer, neurological disorders, and cardiovascular conditions.
Fundamental Principles of PET
Fundamental Principles of PET
684