Related Experiment Video
Updated: Feb 15, 2026

Catheter Ablation in Combination With Left Atrial Appendage Closure for Atrial Fibrillation
Published on: February 26, 2013
Prospective, randomized comparison of 3-dimensional computed tomography guidance versus TEE data for left atrial
Marvin H Eng1, Dee Dee Wang1, Adam B Greenbaum1
1Center for Structural Heart Disease, Division of Cardiology, Henry Ford Health System, Detroit, Michigan.
Background:
Preliminary data comparing 3-dimensional computed tomography (3D-CT) to transesophageal echocardiography (TEE) for left atrial appendage occlusion (LAAO) indicates that 3D-CT provides more accurate measurements and improves case planning. Therefore, we conducted a pilot study comparing 3D-CT to TEE in occluder selection accuracy and procedural efficiency.
Methods:
From May 2016 to February 2017, 24 patients were prospectively randomized to undergo LAAO using either TEE or 3D-CT. The primary endpoint was device accuracy while the secondary endpoints included # devices per case, # guide catheters used per case, # fluoroscopy angles used, procedure time, fluoroscopy time, radiation dose, and major adverse events (stroke, MI, device embolization, perforation, death).
Results:
Procedure success was 100% and 92% for the 3D-CT and 2D-TEE cohorts respectively. Accuracy for 1st device selection 92% and 27% (P = .01) for 3D-CT and 2D-TEE respectively but with intra-procedural upsizing in the 2D-TEE cohort, the 2D-TEE cohort accuracy increased to 64% while the 3D-CT groups 92% was accurate (P = .33). Case planning using 3D-CT was significantly more efficient with respect to device utilization (CT 1.33 ± 0.7 vs. 2D-TEE 2.5 ± 1.2 P = .01), guide catheters (CT 1 vs. 2D-TEE 1.7 ± 0.8 P = .01) and procedure time (3D-CT 55 ± 17 min vs. 2D-TEE 73 ± 24 min P < .05). One major adverse event, a stroke occurred in the 2D-TEE group.
Conclusion:
In this single-center pilot study, CT guided LAAO case planning was associated with improved device selection accuracy and procedural efficiency. This study data supports the notion that comprehensive 3D assessment significantly simplifies LAAO, minimizing the time and number of steps needed.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Surface Appendages of Archaea
Molecular Comparison of Gases, Liquids, and Solids
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Dimensional Analysis
Conversion Factors and Dimensional Analysis
The unit...