Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
A comprehensive two-dimensional gas chromatography valve modulation method using hold-release primary column flow for
Huamin Cai1, Stanley D Stearns1
1Valco Instruments Co. Inc., 8300 Waterbury Drive, Houston, Texas 77055, USA.
Abstract:
A valve modulator with a hold-release primary column flow method has been proposed. This method uses a valve plumbed so that the head and tail of the primary column are connected during the secondary separation, to reverse, slow down, and finally stop the primary column flow. This keeps the sample in the primary column longer, gaining more time for secondary separation. Applying this method, a 60-second secondary retention time with 100% transfer, 133 ms secondary peak width at base, and no primary peak profile loss has been achieved. A standard sample with 19 compounds in 3 groups has been tested. The relative standard deviations for the retention time of this standard mixture are <0.26% for primary dimension and <0.94% for secondary dimension. A gasoline sample analysis with 5, 15, and 30-meter-long secondary columns has been demonstrated. With the secondary column length increase, the secondary separation has greatly improved even though the total run time increases to 45, 110, and 120 min and the toluene primary peak width at base increases to 0.51, 1.81, and 1.85 min respectively. A diesel samplerun by this method has also been demonstrated.
More Related Videos
08:22Nitrogen Compound Characterization in Fuels by Multidimensional Gas Chromatography
Published on: May 15, 2020
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
Related Concept Videos
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Primary and Secondary Growth in Roots and Shoots
Types Of Column Chromatography
Gel Filtration Chromatography
When the...
Principles Of Column Chromatography
Diffusion on Chromatography Columns
Longitudinal diffusion occurs when the solute molecules in the mobile phase diffuse from the more concentrated center of the chromatographic band to the more dilute regions on either side, both towards and against the flow direction. This...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...