Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
A fast temperature-programmed second-dimension column for comprehensive two-dimensional gas chromatography
Huamin Cai1, Stanley D Stearns2
1Valco Instruments Co. Inc., 8300 Waterbury Dr., Houston, TX, 77055, USA. Huamin.cai@vici.com.
Abstract:
The short analysis time and constant temperature environment in the second dimension of two-dimensional comprehensive chromatography frequently causes wraparound problems, especially for complex high boilers. This problem can be solved by temperature programming on the second column, but since this requires heating and cooling the column in a matter of seconds, it is difficult to implement. In this study, we describe a method of accomplishing rapid heating and cooling with a resistively heated column cooled by compressed air. Critical to this method is minimizing the lag time between the actual temperature and the reported temperature by using the column heating element as the temperature sensor, virtually eliminating the danger of overshooting the temperature setpoint. This technique facilitates a ramp rate of up to 100 °C/s with minimal overshooting-well beyond the requirements of gas chromatography. A single-layer column bundle design allows a compressed-air cooling device to cool the column from 200 to 50 °C at an average rate of -21 °C/s. The secondary dimension temperature programming is facilitated by the longer secondary dimension time made possible by the direct flow modulation method. We evaluated the performance of the single-layer column bundle and demonstrated this method by applying it to a gasoline sample. We also compared this method with the traditional isothermal approach and found that use of the secondary temperature program reduced the naphthalene retention time from 12.1 to 6.3 s and its peak width at half height from 846 to 126 ms.
More Related Videos
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
Related Concept Videos
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Types of Detectors-II