Related Experiment Video
Updated: Feb 5, 2026

Graphene Coatings for Biomedical Implants
Published on: March 1, 2013
Biomimetic multilayer coatings deliver gentamicin and reduce implant-related osteomyelitis in rats
Steffi Grohmann1, Manuela Menne1, Diana Hesse1
1Institute for Bioprocessing and Analytical Measurement Techniques (iba) e.V., Department of Biomaterials, 37308 Heilbad Heiligenstadt, Germany.
Abstract:
Implant-related infections like periprosthetic joint infections (PJI) are still a challenging issue in orthopedic surgery. In this study, we present a prophylactic anti-infective approach based on a local delivery of the antibiotic gentamicin. The local delivery is achieved via a nanoscale polyelectrolyte multilayer (PEM) coating that leaves the bulk material properties of the implant unaffected while tuning the surface properties. The main components of the coating, i.e. polypeptides and sulfated glycosaminoglycans (sGAG) render this coating both biomimetic (matrix mimetic) and biodegradable. We show how adaptions in the conditions of the multilayer assembly process and the antibiotic loading process affect the amount of delivered gentamicin. The highest concentration of gentamicin could be loaded into films composed of polypeptide poly-glutamic acid when the pH of the loading solution was acidic. The concentration of gentamicin on the surface could be tailored with the number of deposited PEM layers. The resulting coatings reveal a bacteriotoxic effect on Staphylococcus cells but show no signs of cytotoxic effects on MC3T3-E1 osteoblasts. Moreover, when multilayer-coated titanium rods were implanted into contaminated medullae of rat tibiae, a reduction in the development of implant-related osteomyelitis was observed. This reduction was more pronounced for the multifunctional, matrix-mimetic heparin-based coatings that only deliver lower amounts of gentamicin.
Related Concept Videos
Reducing Line Loss
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
Pinching-off of Coated Vesicles
Clathrin Coated Vesicles
COP Coated Vesicles
Coat Assembly and GTPases
Coat assembly depends on the local availability of phosphatidylinositol phosphates or PIPs and GTP-binding proteins. Adaptor proteins, which link the coat proteins to the membrane, bind to these PIPs and play a crucial role in controlling...
Methods of reducing fever
Pharmacological Methods of Reducing Fever:

