Related Experiment Video
Updated: Feb 3, 2026

Bronchoalveolar Lavage BAL for Research; Obtaining Adequate Sample Yield
Published on: March 24, 2014
Comparison of bronchoscopic and nonbronchoscopic bronchoalveolar lavage in healthy cats
Abstract:
OBJECTIVE To compare bronchoalveolar lavage (BAL) accomplished by use of a bronchoscopic (B-BAL) and a nonbronchoscopic (NB-BAL) technique in healthy cats. ANIMALS 12 healthy cats. PROCEDURES Two BALs were performed in a randomized order 2 weeks apart in each cat. Cats were anesthetized, and a 2.9-mm fiberoptic bronchoscope (B-BAL) or 8F red rubber catheter (NB-BAL) was wedged in a bronchus. Two 5-mL aliquots of saline (0.9% NaCl) solution were infused into the left and right caudal lung fields and aspirated manually with a 20-mL syringe. Proportion of BAL fluid (BALF) retrieved, depth of wedging, and anesthetic complications were recorded. Total nucleated cell count, differential cell count, and semiquantitative scores of cytologic slide quality were determined for all BALF samples. Results were compared with ANOVAs and Wilcoxon signed rank tests. RESULTS Proportion of retrieved BALF and depth of wedging were significantly greater for B-BAL than NB-BAL. Differential cell counts and cytologic slide quality did not differ significantly between techniques. Complications included transient hemoglobin desaturation (24/24 [100%] BALs) and prolonged anesthetic recovery time (4/24 [17%] BALs). Anesthetic recovery scores did not differ significantly between techniques. CONCLUSIONS AND CLINICAL RELEVANCE Results indicated that NB-BAL was noninferior to B-BAL with regard to ease of performance, anesthetic variables, and cytologic slide quality for cats without clinical respiratory tract disease.
Related Concept Videos
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
Evolutionary Relationships through Genome Comparisons
Comparison Between Electrical And Gravitational Forces
Since both are inverse square law forces, the distance gets canceled when the ratio of the two forces is considered. Instead, the ratio of the electrical and gravitational forces depends on...
Comparison between RL and RC circuits
Molecular Comparison of Gases, Liquids, and Solids

