Related Experiment Video
Updated: Feb 1, 2026

Software-Assisted Quantitative Measurement of Osteoarthritic Subchondral Bone Thickness
Published on: March 18, 2022
Repeatability and Reproducibility of Peripapillary Choroidal Thickness Using a Medical Image-Processing Software.
Pedro Simoes1, Pedro Silva1, Miguel Cordeiro1
1Ophthalmology Department, Egas Moniz Hospital, CHLO, Lisbon, Portugal.
This study introduces a new method using ImageJ software to accurately measure Peripapillary Choroidal Thickness (PPCT). The novel technique demonstrated excellent reproducibility and repeatability in healthy volunteers, supporting its clinical use.
Area of Science:
- Ophthalmology
- Medical Imaging
- Image Processing
Background:
- The choroid's role in ocular diseases is significant but not fully understood for all conditions.
- Accurate measurement of Peripapillary Choroidal Thickness (PPCT) is crucial for understanding choroidal function.
- Existing methods for PPCT assessment may lack precision or require further validation.
Purpose of the Study:
- To develop and validate a novel methodology for accurate Peripapillary Choroidal Thickness (PPCT) measurement.
- To assess the reproducibility and repeatability of PPCT evaluation using ImageJ software.
- To establish the feasibility of this image-processing technique in clinical settings.
Main Methods:
- Utilized Spectral-domain Optical Coherence Tomography (SD-OCT) for imaging acquisition.
- Employed ImageJ software for Peripapillary Choroidal Thickness (PPCT) area determination.
- Conducted a study with 24 healthy volunteers (48 eyes) assessed by two blinded observers across two sessions.
Main Results:
- The proposed ImageJ-based methodology demonstrated high inter-observer and intra-observer agreement.
- Intra-class Correlation Coefficient (ICC) values were consistently high (0.994-0.998).
- Concordance Correlation Coefficient (CCC) values further supported excellent agreement (0.996-0.999).
Conclusions:
- The novel ImageJ-based methodology for PPCT quantification is feasible and highly reproducible.
- The technique shows excellent inter- and intra-observer agreement, validating its reliability.
- This approach holds potential for use in diverse clinical settings to advance the understanding of choroidal pathology.
Related Concept Videos
Inhaled Medications
Design Example: Deciding Thickness of Lubricating Fluid in a Shaft
To calculate the required thickness of the lubricant layer, the tangential velocity at the shaft's surface must first be determined. This velocity is calculated by converting the rotational speed to angular velocity...
Endocarditis III: Medical Management
Myocarditis III: Medical Management
Pericarditis III: Medical Management
Heart Failure V: Medical Management