Related Experiment Video
Updated: Jan 30, 2026

An Anesthesia, Surgery, and Harvest Method for the Evaluation of Transpedicular Screws Using an In Vivo Porcine Lumbar Spine Model
Published on: May 31, 2017
Morphometric Analysis of the Lumbar Vertebrae Concerning the Optimal Screw Selection for Transpedicular Stabilization
Jarosław Dzierżanowski1, Monika Skotarczyk2, Zuzanna Baczkowska-Waliszewska2
1Department of Neurosurgery, Faculty of Medicine, Medical University of Gdansk, Gdansk, Poland.
Abstract:
Transpedicular stabilization is a frequently used spinal surgery for fractures, degenerative changes, or neoplastic processes. Improper screw fixation may cause substantial vascular or neurological complications. This study seeks to define detailed morphometric measurements of the pedicle (height, width, and surface area) in the aspects of screw length and girth selection and the trajectory of its implantation, i.e., sagittal and transverse angle of placement. The study was based on CT examinations of 100 Caucasian patients (51 women and 49 men) aged 27-75 with no anatomical, degenerative, or post-traumatic spine changes. The results were stratified by gender and body side, and they were counter compared with the available literature database. Pedicle height decreased from L1 to L4, ranging from 15.9 to 13.3 mm. Pedicle width increased from L1 to L5, extending from 6.1 to 13.2 mm. Pedicle surface area increased from L1 to L5, ranging from 63 to 140 mm2. Distance from the point of entry into the pedicle to the anterior surface of the vertebral body, defining the maximum length of a transpedicular screw, varied from 54.0 to 50.2 mm. Variations concerning body sides were inappreciable. A transverse angle of screw trajectory extended from 20° to 32°, shifting caudally from L1 to L5, with statistical differences in the L3-L5 segments. A sagittal angle varied from 10° to 12°, without such definite relations. We conclude that the L1 and L2 segments display the most distinct morphometric similarities, while the greatest differences, in both genders, are noted for L3, L4, and L5. The findings enable the recommendation of the following screw diameters: 4 mm for L1-L2, 5 mm for L3, 6 mm for L4-L5, and the length of 50 mm. We believe the study has extended clinical knowledge on lumbar spine morphometry, essential in the training physicians engaged in transpedicular stabilization.
Related Concept Videos
General Structure of a Vertebra
Screw: Problem Solving
To evaluate the...
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
Frictional Forces on Screws
A jack with a square-threaded screw is a mechanical device used to lift heavy loads by applying a force at its handle. When the force is applied, the screw turns, raising the load. The screw can...
Nuclear Stability
To hold positively charged protons together...
RNA Stability

