Related Experiment Video
Updated: Jan 26, 2026

Measuring Attentional Biases for Threat in Children and Adults
Published on: October 19, 2014
Comparing Three Different Contrast Sensitivity Tests in Adults and in Children with and without Amblyopia
Kerstin Ulrich1, Anja Palmowski-Wolfe1
1University Eye Hospital Basel, Basel, Switzerland.
Background:
Tests of contrast sensitivity (CS) are not routinely performed in the clinic, although CS is reduced in many conditions, such as amblyopia or glaucoma. This may be due to perceived time constraints or unaffordability of equipment.
Patients And Methods:
Monocular CS functions obtained with the FACT, CSV 1000E, and Lea Symbols were compared in 19 healthy subjects aged 24 - 78 years and 24 subjects aged 5 - 16 years, 9 of whom had amblyopia.
Results:
CS functions could be obtained with all three tests. The tests were equally comfortable for young and adult patients, and took less than 5 minutes to perform (one eye). All measured CSs at 3, 6, 12, and 18 cycles per degree (cpd), but the FACT included 1.5 cpd. LINEAR MIXED EFFECT MODELS: were performed. While there was no significant difference at low spatial frequencies, the Lea CS test showed a ceiling effect in that range, while the FACT showed a floor effect at high spatial frequencies. CS in amblyopic children did not differ between the contralateral and the amblyopic eye. Overall, amblyopic eyes had lower CS values than the control eyes and CS did not correlate significantly to visual acuity at distance.
Conclusion:
All three CS tests could be usefully applied in the clinic in adults as well as children over the age of 4 years. Only the CSV 1000E exhibited neither a ceiling nor a floor effect. This was also the fastest test. In children with amblyopia, CS testing offers additional information on visual function. In contrast to previous reports, we did not find that the CSV and FACT are interchangeable.
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Comparative Excretory Systems
Comparing Copy Number Variations and SNPs
Copy number variations or CNVs are the structural variations that cover more than 1kb of DNA sequence. The single nucleotide polymorphism (SNP), on the other hand, is a single nucleotide change or a point mutation that is found in more than 1%...
Comparing the Survival Analysis of Two or More Groups
Comparing Experimental Results: Student's t-Test
Comparing Intermolecular Forces: Melting Point, Boiling Point, and Miscibility
Temporary attractive forces like dispersion are present in all molecules, whether they are polar or nonpolar. They...

