An interval-estimation-based anti-disturbance sliding mode control strategy for rigid satellite with prescribed

Zepeng Zhou1, Fanglai Zhu1, Dezhi Xu2

  • 1College of Electronics and Information Engineering, Tongji University, Shanghai 201804, China.

ISA Transactions
|June 6, 2020
PubMed

Related Concept Videos

Circular Orbits and Critical Velocity for Satellites01:16

Circular Orbits and Critical Velocity for Satellites

The Moon orbits around the Earth. In turn, the Earth (and other planets) orbit the Sun. The space directly above our atmosphere is filled with artificial satellites in orbit. One can examine the circular orbit, the simplest kind of orbit, to understand the relationship between the speed and the period of planets and satellites with respect to their positions and the bodies that they orbit.
Nicolaus Copernicus (1473-1543) first suggested that the Earth and all other planets orbit the Sun in...
5.3K
Uniform Circular Motion01:14

Uniform Circular Motion

Uniform circular motion is a specific type of motion in which an object travels in a circle with a constant speed. For example, any point on a propeller spinning at a constant rate is undergoing uniform circular motion. The second, minute, and hour hands of a watch also undergo uniform circular motion. It is hard to believe that points on these rotating objects are actually accelerating, even though the rotation rate is constant. To understand this, we must analyze the motion in terms of...
21.3K
Time-Domain Interpretation of PD Control01:07

Time-Domain Interpretation of PD Control

Proportional-Derivative (PD) control is a widely used control method in various engineering systems to enhance stability and performance. In a system with only proportional control, common issues include high maximum overshoot and oscillation, observed in both the error signal and its rate of change. This behavior can be divided into three distinct phases: initial overshoot, subsequent undershoot, and gradual stabilization.
Consider the example of control of motor torque. Initially, a positive...
303
Time and frequency -Domain Interpretation of PI Control01:27

Time and frequency -Domain Interpretation of PI Control

Proportional-Integral (PI) controllers are essential in many control systems to improve stability and performance. They are commonly used in everyday devices like thermostats to enhance system damping and reduce steady-state error. When the zero in the controller's transfer function is optimally placed, the system benefits significantly in terms of stability and accuracy.
Acting as a low-pass filter, the PI controller slows the system's response and extends settling times. This requires...
342
Linear Approximation in Time Domain01:21

Linear Approximation in Time Domain

Nonlinear systems often require sophisticated approaches for accurate modeling and analysis, with state-space representation being particularly effective. This method is especially useful for systems where variables and parameters vary with time or operating conditions, such as in a simple pendulum or a translational mechanical system with nonlinear springs.
For a simple pendulum with a mass evenly distributed along its length and the center of mass located at half the pendulum's length,...
267
Errors in Global Positioning System01:26

Errors in Global Positioning System

Global Positioning System (GPS) technology has revolutionized navigation and positioning, but its accuracy is often compromised by various errors. These errors, stemming from environmental, satellite, and receiver-related factors, require careful mitigation to ensure reliable performance across applications.Atmospheric ErrorsGPS signals travel through the Earth’s ionosphere and troposphere, introducing delays which affect accuracy. The ionosphere is strongly influenced by charged particles,...
252