A vinylpyrrolidone-based thin film microextraction in combination with direct solid-state spectrofluorimetry for determination of sartans in human plasma
Related Experiment Video
Updated: Dec 18, 2025

Evaluation of Drug Sorption to PVC- and Non-PVC-based Tubes in Administration Sets Using a Pump
Published on: March 11, 2017
Sima Najafi Ghamat1, Zahra Talebpour1
1Department of Chemistry, Faculty of Physics and Chemistry, Alzahra University, Vanak, Tehran, 19835-389, Iran.
Abstract:
A vinylpyrrolidone-ethylene glycol dimethacrylate-acrylic acid thin film was prepared on a polypropylene guard and its formulation was optimized for application in thin film microextraction followed by direct solid-state spectrofluorimetry method. The surface morphology, fluorescence property and extraction performance of the thin film were investigated systematically. The intra- and inter-batch reproducibilities of thin film fabrication were obtained 2.3 and 4.2%, respectively. The lifetime of each prepared thin film was 30 times with a relative standard deviation of less than 1.4%. The developed method was optimized for extraction of some sartans as angiotensin II receptors antagonist (including losartan, valsartan, and olmesartan) which have been used to control hypertension as the main causes of cardiovascular disease. The optimum extraction conditions achieved at 2- (for losartan) and 4- (for valsartan and olmesartan) sample pH, 500-rpm rotation rate and 30-min extraction time for all three analytes. At the optimum conditions, analyses of losartan, valsartan, and olmesartan were validated in the human plasma matrix. Broad linearity ranges with determination coefficients of more than 0.999 were achieved for each calibration curve. Limit of detection of the method was 0.5 ng mL-1 for all three analytes. The intra- and inter-day accuracies and precisions of the developed method were evaluated in spiked plasma samples at three concentration levels of each analyte with high recoveries of 95-101% and relative standard deviations less than 6%. This method provides a simple, sensitive, fast, and high-throughput analysis method with the possibility of effective extraction of at least 40 samples simultaneously without the necessity of protein precipitating, desorption, and solvent evaporation steps.
More Related Videos
13:35A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
08:41Integration of Miniaturized Solid Phase Extraction and LC-MS/MS Detection of 3-Nitrotyrosine in Human Urine for Clinical Applications
Published on: July 14, 2017