Related Experiment Video
Updated: Oct 7, 2025

Catheter Ablation in Combination With Left Atrial Appendage Closure for Atrial Fibrillation
Published on: February 26, 2013
Gore Cardioform ASD device thrombus weeks after COVID-19 infection
Liliam Aquino1, Juan Carlos Muniz2, Pablo Marcelo Laufer3
1Department of Pediatrics, Nicklaus Children's Hospital, Miami, Florida, USA.
Abstract:
Device-related thrombosis and device-related endocarditis after atrial septal defect (ASD) transcatheter closure are extremely rare. It is known that COVID-19 infection could lead to a thrombotic microangiopathy-like phenomenon. We present the case of a 14-year-old female who developed fever and was found to have a thrombus on the right atrial side of the ASD closure device weeks after an asymptomatic COVID-19 infection and negative COVID-19 test 2 days before transcatheter ASD closure. Although there is no certainty that the thrombus was related to the prior COVID-19 infection, the possibility of an ongoing COVID-19-related hypercoagulable state should be entertained.