Related Experiment Video
Updated: Sep 25, 2025

Assessing Binocular Central Visual Field and Binocular Eye Movements in a Dichoptic Viewing Condition
Published on: July 21, 2020
Calibration method for structure parameters of a binocular stereo vision system equipped with polarizers
Abstract:
For structure parameter calibration of a binocular stereo vision system equipped with polarizers, the optimal calibration polarization angle needs to be determined. There are no corresponding solutions for the determination of the optimal polarization angle of structure parameter calibration. Furthermore, existing research considers the polarization angle that causes the image to possess the lowest brightness (gray value) as the optimal polarization angle. This reduces image contrast, and eventually the texture information of the image is lost, which also affects the accuracy of feature extraction. In this paper, we propose a new calibration method for the structure parameters of a binocular stereo vision system equipped with polarizers. We calculated the pose of the target relative to each camera for different polarization angles. The sum of the object-space errors corresponding to each polarization angle was considered as the evaluation criterion to determine the optimal calibration polarization angle. The calibration of structure parameters was finished using images captured on the premise of the optimal calibration polarization angle. This angle can also be considered as the reference of the polarization angle for measurement. Experiment results show that using the calibration results of our method, the reconstructed length error of a 275×200mm target was less than ±0.052mm, the reconstructed linear displacement error was less than ±0.048mm for the range of 0-30 mm, and the reconstructed rotary angle error was less than ±0.048∘ for the range of-30∘-30∘.
More Related Videos
06:19Comparison of Three Clinical Stereoscopic Methods for Measuring Binocular Visual Function During Amblyopic Treatment in Unilateral Amblyopia
Published on: September 27, 2024
05:12Robotized Testing of Camera Positions to Determine Ideal Configuration for Stereo 3D Visualization of Open-Heart Surgery
Published on: August 12, 2021
Related Concept Videos
Polar and Cylindrical Coordinates
Curvilinear Motion: Polar Coordinates
The particle's location is described using a unit vector along the radial direction. Deriving the particle's position...
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...
Calibration Curves: Correlation Coefficient