Related Experiment Video
Updated: Aug 29, 2025

Isokinetic Robotic Device to Improve Test-Retest and Inter-Rater Reliability for Stretch Reflex Measurements in Stroke Patients with Spasticity
Published on: June 12, 2019
Inter-rater Reliability of the Classification of the J-Sign Is Inadequate Among Experts
Laurie A Hiemstra1,2, Brendan Sheehan3,4, Treny M Sasyniuk1
1Banff Sport Medicine Foundation, Banff, AB, Canada.
Objective:
The purpose of this study was to determine the inter-rater and intra-rater reliability of the symmetry, classification, and underlying pathoanatomy associated with the J-sign in patients with recurrent lateral patellofemoral instability.
Study Design:
Blinded, inter-rater reliability study.
Setting:
N/A.
Participants:
Thirty patellofemoral joint experts.
Interventions:
Thirty clinicians independently assessed 30 video recordings of patients with recurrent lateral patellofemoral instability performing the J-sign test.
Main Outcome Measures:
Raters documented J-sign symmetry and graded it according to the quadrant and Donell classifications. Raters indicated the most significant underlying pathoanatomy and presence of sagittal plane maltracking. Intra-rater reliability was assessed by 4 raters repeating the assessments. Mean pairwise simple and/or weighted Cohen's kappa were performed to measure inter-rater and intra-rater reliability, as well as calculation of percent agreement.
Results:
J-sign symmetry demonstrated fair inter-rater reliability (k = 0.26), whereas intra-rater reliability was moderate (k = 0.48). Inter-rater reliability for the quadrant and Donell classifications indicated moderate agreement, k = 0.51 and k = 0.49, respectively, whereas intra-rater reliability was k = 0.79 and k = 0.72, indicating substantial agreement. Inter-rater reliability of the foremost underlying pathoanatomy produced only slight agreement (k = 0.20); however, intra-rater reliability was substantial (k = 0.68). Sagittal plane maltracking demonstrated slight inter-rater agreement (k = 0.23) but substantial intra-rater agreement (k = 0.64).
Conclusions:
The symmetry, classification, and underlying pathoanatomy of the J-sign demonstrated fair to moderate inter-rater reliability and moderate to substantial intra-rater reliability among expert reviewers using video recordings of patients with recurrent lateral patellofemoral instability. These findings suggest individual raters have a consistent standard for assessing the J-sign, but that these standards are not reliable between assessors.
Level Of Evidence:
III.
Related Concept Videos
Classification of Systems-II
Classification of Signals
A continuous-time signal holds a value at every instant in time, representing information seamlessly. In contrast, a discrete-time signal holds values only at specific moments, often denoted as x(n), where...
Classification of Systems-I
Homogeneity dictates that if an input x(t) is multiplied by a constant c, the output y(t) is multiplied by the same constant. Mathematically, this is expressed as:
Sign Test for Nominal Data
For example, consider a...
Structural Classification of Joints
A fibrous joint is where the adjacent bones are united by fibrous connective...
Reliability and Validity