Introduction:
The use of high throughput patch clamp profiling to determine mixed ion channel-mediated arrhythmia risk was assessed using profiling data generated using proprietary internal and clinical reference compounds. We define the reproducibility of the platform and highlight inherent platform issues. The data generated was used to develop predictive models for cardiac arrhythmia risk, specifically Torsades de Pointes (TdP).
Methods:
A retrospective analysis was performed using profiling data generated over a 3-year period, including patch clamp data from hERG, Cav1.2, and Nav1.5 (peak/late), together with hERG binding.
Results:
Assay reproducibility was robust over the 3-year period examined. High throughput hERG patch IC50 values correlated well with GLP-hERG data (Pearson = 0.87). A disconnect between hERG binding and patch was observed for ∼10% compounds and trended with passive cellular permeability. hERG and Cav1.2 potency did not correlate for proprietary compounds, with more potent hERG compounds showing selectivity versus Cav1.2. For clinical compounds where hERG and Cav1.2 activity was more balanced, an analysis of TdP risk versus hERG/Cav1.2 ratio demonstrated low TdP probability when the hERG/Cav1.2 potency ratios were < 1. Modeling of clinical compound data revealed a lack of impact of the Nav1.5 (late) current in predicting TdP. Moreover, models using hERG binding data (ROC AUC = 0.876) showed an improved ability to predict TdP risk versus hERG patch clamp (ROC AUC = 0.787).
Discussion:
The data highlight the value of high throughput patch clamp data in the prediction of TdP risk, as well as some potential limitations with this approach.
More Related Videos
10:41Laser-Induced Action Potential-Like Measurements of Cardiomyocytes on Microelectrode Arrays for Increased Predictivity of Safety Pharmacology
Published on: September 13, 2022
11:13Electrophysiological Analysis of human Pluripotent Stem Cell-derived Cardiomyocytes hPSC-CMs Using Multi-electrode Arrays MEAs
Published on: May 12, 2017
Related Concept Videos
Mechanism of Cardiac Arrhythmias
Patch Clamp
In this method, a glass micropipette containing electrolyte solution is tightly sealed against a small portion of the cell membrane. As a result, a patch of the cell...
Antiarrhythmic Drugs: Class III Agents as Potassium Channel Blockers
Dysrhythmias II: Classification of Tachyarrhythmias
Antiarrhythmic Drugs: Class I Agents as Sodium Channel Blockers
Class 1A Antiarrhythmic Drugs: These drugs work by moderately blocking sodium channels,...
Dysrhythmias V: Evaluating Dysrhythmias