Electrocardiogram to Determine Mitral and Aortic Valve Opening and Closure
M Rifqi Aufan1, Zachary T Jost2, Neal J Miller2
1Department of Biomedical Engineering, University of Alabama at Birmingham, Birmingham, AL, USA.
Purpose:
Knowledge of the timing of cardiac valve opening and closing is important in cardiac physiology. The relationship between valve motion and electrocardiogram (ECG) is often assumed, however is not clearly defined. Here we investigate the accuracy of cardiac valve timing estimated using only the ECG, compared to Doppler echocardiography (DE) flow imaging as the gold standard.
Methods:
DE was obtained in 37 patients with simultaneous ECG recording. ECG was digitally processed and identifiable features (QRS, T, P waves) were examined as potential reference points to determine opening and closure of aortic and mitral valves, as compared to DE outflow and inflow measurement. Timing offset of the cardiac valves opening and closure between ECG features and DE was measured from derivation set (n = 19). The obtained mean offset in combination with the ECG features model was then evaluated on a validation set (n = 18). Using the same approach, additional measurement was also done for the right sided valves.
Results:
From the derivation set, we found a fixed offset of 22 ± 9 ms, 2 ± 13 ms, 90 ± 26 ms, and - 2 ± - 27 ms when comparing S to aortic valve opening, Tend to aortic valve closure, Tend to mitral valve opening, and R to mitral valve closure respectively. Application of this model to the validation set showed good estimation of aortic and mitral valve opening and closure timing value, with low model absolute error (median of the mean absolute error of the four events = 19 ms compared to the gold standard DE measurement). For the right-sided (tricuspid and pulmonic) valves in our patient set, there was considerably higher median of the mean absolute error of 42 ms for the model.
Conclusion:
ECG features can be used to estimate aortic and mitral valve timings with good accuracy as compared to DE, allowing useful hemodynamic information to be derived from this easily available test.
More Related Videos
Related Concept Videos
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Mitral Regurgitation I: Introduction
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Mitral Stenosis II: Clinical features and Diagnostic Tests
Mitral Regurgitation II: Clinical Features and Diagnostic Tests
Aortic Regurgitation II: Clinical Features and Diagnostic Tests