Related Experiment Video
Updated: May 16, 2025

Optimized Setup and Protocol for Magnetic Domain Imaging with In Situ Hysteresis Measurement
Published on: November 7, 2017
MEMS-based narrow-bandwidth magnetic field sensors: preliminary assessment of prototypes regarding coercivity,
Negar Ziehm1, Johan Arbustini2, Eric Elzenheimer3,4
1Chair for Composite Materials, Department of Materials Science, Faculty of Engineering, 546314 Kiel University , Kiel, Germany.
Objectives:
This study evaluates micro-electro-mechanical systems (MEMS) devices comprising cantilever piezoelectric resonators with powder-based permanent magnets (micromagnets) at the tip. Fabricated using a well-known PowderMEMS process given by the Fraunhofer Institute for Silicon Technology, these devices function as magnetic field sensors based on the magnetic torque detection principle, which arises from the interaction between the given micromagnets' dipole moment and the to-be-measured magnetic field. The study investigates how the magnetic state of the micromagnets influences the overall sensitivity of the provided Prototype MEMS-devices.
Methods:
The performance of the first prototypes of this narrow-band magnetic field sensor was evaluated using two approaches: (1) a Vibrating Sample Magnetometer (VSM) to analyze the magnetic hysteresis loop and (2) sensitivity measurements at resonance frequency to determine the provided sensitivity under a predefined external magnetic flux density.
Results:
Among the four prototypes analyzed, the device with the highest remanence and coercivity demonstrated superior sensing performance, achieving a sensitivity of 1,090 kV/T at the resonance frequency. The analysis showcased substantial variations in noise amplitude spectral density, and sensitivity, emphasizing the importance of magnetic hysteresis properties in sensor performance.
Conclusions:
These findings highlight the potential of MEMS-devices with enhanced coercivity and remanence for enhanced sensing capabilities in compact sensor designs, particularly useful for array sensor configurations in narrow-bandwith medical applications.
More Related Videos
07:42Optimizing Magnetic Force Microscopy Resolution and Sensitivity to Visualize Nanoscale Magnetic Domains
Published on: July 20, 2022
06:17Quantifying the Relative Thickness of Conductive Ferromagnetic Materials Using Detector Coil-Based Pulsed Eddy Current Sensors
Published on: January 16, 2020
Related Concept Videos
Magnetic Susceptibility and Permeability
When diamagnetic materials are placed under an external magnetic field, the moments opposite to the field are induced. Hence, the susceptibility for diamagnets has a minimal negative value of 10-5–10-6. Since...
Ferromagnetism
Magnetic Damping
If, however, the bob is a slotted metal plate, the magnet produces a much smaller effect. When a slotted metal plate enters the field, an emf is induced by the change in flux; however, it is less effective because the slots limit the...
Magnetic Field Of A Current Loop
Magnetic Resonance Imaging
Diamagnetism
Diamagnetism was discovered by Anton Brugmans in 1778 when he observed that bismuth gets repelled by magnetic fields, thus theorizing that diamagnets get repelled by magnets....