Related Experiment Video
Updated: Mar 9, 2026

Computed Tomography-guided Time-domain Diffuse Fluorescence Tomography in Small Animals for Localization of Cancer Biomarkers
Published on: July 17, 2012
Fast and Robust Reconstruction for Fluorescence Molecular Tomography via L1-2 Regularization
Haibo Zhang1, Guohua Geng1, Xiaodong Wang1
1School of Information Sciences and Technology, Northwest University, Xi'an, Shaanxi 710027, China.
Abstract:
Sparse reconstruction inspired by compressed sensing has attracted considerable attention in fluorescence molecular tomography (FMT). However, the columns of system matrix used for FMT reconstruction tend to be highly coherent, which means L1 minimization may not produce the sparsest solution. In this paper, we propose a novel reconstruction method by minimization of the difference of L1 and L2 norms. To solve the nonconvex L1-2 minimization problem, an iterative method based on the difference of convex algorithm (DCA) is presented. In each DCA iteration, the update of solution involves an L1 minimization subproblem, which is solved by the alternating direction method of multipliers with an adaptive penalty. We investigated the performance of the proposed method with both simulated data and in vivo experimental data. The results demonstrate that the DCA for L1-2 minimization outperforms the representative algorithms for L1, L2, L1/2, and L0 when the system matrix is highly coherent.
Related Concept Videos
Super-resolution Fluorescence Microscopy
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Confocal Fluorescence Microscopy