Related Experiment Video
Updated: Feb 3, 2026

Identifying Coronary Artery Calcification on Non-gated Computed Tomography Scans
Published on: August 28, 2018
Prognostic Performance of Prospective versus Retrospective Electrocardiographic Gating in Coronary Computed
Abstract:
Coronary computed tomographic angiography (CCTA) with prospective electrocardiographic gating reduces radiation exposure, but its prognostic power for predicting cardiovascular risk in patients with suspected CAD has not been fully validated. To determine whether prospective gating performs as well as retrospective gating in this population, we compared these scan modes in patients undergoing 64-slice CCTA. From January 2009 through September 2011, 1,407 patients underwent CCTA; of these, 915 (mean age, 57.8 ± 13.5 yr; 54% male) had suspected coronary artery disease at the time of CCTA and were included in the study. Prospective gating was used in 195 (21%) and retrospective gating in 720 (79%). The mean follow-up duration was 2.4 ± 0.9 years. Overall, 390 patients (42.6%) had normal results on CCTA, 382 (41.7%) had nonobstructive coronary artery disease, and 143 (15.6%) had obstructive disease. Major adverse cardiac events occurred in 32 patients (3.5%): 11 cardiac deaths, 15 late revascularizations, and 6 nonfatal myocardial infarctions. Total event occurrences were similar in both groups (retrospective, 3.8%; prospective, 2.6%; P=0.42), as were the occurrences of each type of event. On adjusted multivariate analysis, nonobstructive (P=0.015) and obstructive (P <0.001) coronary artery disease were independently associated with major adverse cardiac events. Scan mode was not a predictor of outcome. The mean effective radiation dose was 4 ± 2 mSv for prospective compared with 12 ± 4 mSv for retrospective gating (P <0.01). The prognostic value of CCTA with prospective electrocardiographic gating compares favorably with that of retrospective gating, and it involves significantly less radiation exposure.
Related Concept Videos
Underflow Gates
Ligand-Gated Ion Channel Receptor: Gating Mechanism
Coronary Circulation
Coronary circulation begins at the base of the aorta, where two main arteries arise—the left and right coronary arteries. These arteries encircle the heart in the coronary sulcus and supply the...
Non-gated Ion Channels
Compared to the gated ion channels, the non-gated channels, also known as leakage or passive channels, have no gating mechanism....
Mechanically-gated Ion Channels
Design Example: Forces in Sluice Gate
Key variables in...

