Related Experiment Video
Updated: Jan 27, 2026

Guided Endodontics: Three-Dimensional Planning and Template-Aided Preparation of Endodontic Access Cavities
Published on: May 24, 2022
Debris extrusion by glide-path establishing endodontic instruments with different geometries
Jung-Hong Ha1, Sung Kyo Kim1, Sang Won Kwak2
1Department of Conservative Dentistry, School of Dentistry, IHBR, Kyungpook National University, Daegu, South Korea.
Background/Purpose:
Glide-path preparation is an important step during initial endodontic procedure to reduce shaping-instrument fracture. The aim of this study was to evaluate the amount of apically extruded debris produced by glide-path preparation instruments with different geometric designs.
Materials And Methods:
Forty teeth extracted for periodontal reasons were randomly divided into four groups (n = 10). The working length was standardized at 17 mm from the apical foramen by a flattening reference point. The glide-path was created using repetitive up-and-down movement three times with one of following four selected instruments: One G, ProGlider, a size 15 ScoutRace, and a size 15 stainless-steel K-file. To collect the apically extruded debris, the customized apparatus was used, and the collected debris was stored in an incubator. The weight of the debris was measured using an analytical balance with an accuracy of 0.00001 g. The data were analyzed by one-way analysis of variance and Duncan's multiple comparison test at a significance level of 95%.
Results:
The ProGlider group produced significantly less debris extrusion relative to the other groups (P < 0.05). The One G and ScoutRace groups showed no significant difference, but debris production was lower than that observed for the stainless-steel group (P < 0.05).
Conclusion:
Creating the glide-path using nickel-titanium rotary files produced lower amounts of debris extrusion than using manual stainless-steel files. The progressive taper design of ProGlider, the center-off cross-section of One G, and the alternative-pitch design of ScoutRace may have increased the efficiencies of debris removal with minimal extrusion during glide-path preparation. Glide-path preparation using NiTi rotary files have better clinical efficiency than the manual stainless-steel file.
Related Concept Videos
Coordination Number and Geometry
Predicting Molecular Geometry
Path Between Thermodynamics States
Mean free path and Mean free time
Behavior of Gas Molecules: Molecular Diffusion, Mean Free Path, and Effusion
Interference: Path Lengths
Two special sources may be considered when they are in phase. This can be easily achieved by feeding the two sources from the same source. An example would be synchronizing the two speakers by feeding them with the same source, such as the sound waves produced by a tuning fork. This setup ensures that the two sources have the same frequency and are...