Evaluating polyvinylidene fluoride - carbon black composites as solid phase microextraction coatings for the detection of urinary volatile organic compounds by gas chromatography-mass spectrometry
Related Experiment Video
Updated: Aug 22, 2025

Capturing Actively Produced Microbial Volatile Organic Compounds from Human-Associated Samples with Vacuum-Assisted Sorbent Extraction
Published on: June 1, 2022
Mark Woollam1, Paul Grocki1, Eray Schulz1
1Department of Chemistry and Chemical Biology, Indiana University-Purdue University, Indianapolis, IN 46202, USA; Integrated Nanosystems Development Institute, Indiana University-Purdue University, Indianapolis, IN 46202, USA.
Abstract:
Volatile organic compounds (VOCs) are biomarkers of disease, which can be utilized for accurate diagnostics. The gold standard for VOC identification is gas chromatography-mass spectrometry (GC-MS) as it allows for structure elucidation and quantification. Headspace solid phase microextraction (HS-SPME) is often used in biomarker discovery due to its ability to preconcentrate VOCs prior to GC-MS analysis. However, HS-SPME GC-MS is time-consuming, expensive and requires trained personnel. Gas sensor arrays can detect VOC biomarkers at a point-of-care and therefore are more suitable for disease diagnostics in the clinic. Nevertheless, qualification and optimization of sensing layers is tedious as each VOC of interest needs to be tested individually. Therefore, using SPME fibers to extract VOCs and GC-MS to quantitate the analytes may be an efficient strategy with high throughput to tune sensing layers and increase analyte affinity. To investigate this, suspensions of polyvinylidene fluoride (PVDF) and polyvinylidene fluoride-carbon black (PVDF-CB) fabricated at varying concentration were immobilized on SPME fibers through physical deposition, used to extract urinary VOCs and were subject to GC-MS analysis. The addition of CB shows increased fiber performance in terms of total integrated signal and sensitivity toward individual VOCs. PVDF-CB fibers were compared to a commercial polydimethylsiloxane (PDMS) SPME fiber run using the same method. The PVDF-CB fiber outperformed the commercial fiber in detecting numerous urinary VOCs of interest. Results of this study show not only that custom SPME fiber performance can be evaluated through GC-MS analysis, but the capability of custom fibers to adsorb urinary VOCs can be tuned based on properties of interest. Hence, this method may be utilized as an analytical tool to characterize and tune gas sensing layers with high analytical throughput.
More Related Videos
05:31Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
05:29Profiling Volatile Compounds in Blackcurrant Fruit using Headspace Solid-Phase Microextraction Coupled to Gas Chromatography-Mass Spectrometry
Published on: June 9, 2021
Related Concept Videos
Gas Chromatography: Types of Detectors-II
High-Performance Liquid Chromatography: Types of Detectors
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...