Aim And Objective:
This study aimed to investigate and compare compressive strength and flexural strength of self-cured Cention N with dual-cured Cention N.
Materials And Methods:
Cention N is mixed according to the proportions, as mentioned by the manufacturer. Dual cured samples are cured using a diode that emits blue light. Cylindrical plexiglass split mold of dimension 6 mm height, and 4 mm diameter used to fabricate samples for compressive strength. Compressive strength tested using Instron universal testing machine. Rectangular plexiglass split mold of dimension 25 mm length, 2 mm height, and 2 mm width were used to fabricate samples for flexural strength. Flexural strength tested using Instron universal testing machine. To compare the mean values independent t-test was used and the significance of the study was measured by calculating a p-value.
Result:
There is no statistically significant difference between compressive strength and flexural strength of self-cured Cention N with dual-cured Cention N.
Conclusion:
The type of polymerization does not affect flexural strength and compressive strength of Cention N.
Clinical Significance:
Self-curing polymerization alone is sufficient for Cention N to achieve adequate compressive strength and flexural strength. So it can be inserted as a single layer on a prepared cavity and to fasten curing additional light curing can be used.
How To Cite This Article:
Fousiya Ks, Balagopal VR, Suresh KJ, et al. Comparative Evaluation of Compressive Strength and Flexural Strength of Self-cured Cention N with Dual-cured Cention N: An In Vitro Study. Int J Clin Pediatr Dent 2022;15(2):210-214.
More Related Videos
Related Concept Videos
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Relation Between Tensile Strength and Compressive Strength of Concrete
Accelerated Curing of Concrete
Tensile Strength Considerations of Concrete
The dimensions and shape of a concrete specimen...
Impact Strength of Concrete
Curing of Concrete