Distributed resilient consensus for heterogeneous fractional-order multi-agent systems against hybrid attacks
Yuhan Yang1, Daduan Zhao2, Jin You1
1School of Control Science and Engineering, Shandong University, Jinan, 250061, China.
ISA Transactions
|June 16, 2026
Summary
This study introduces a fractional-order control framework for heterogeneous multi-agent systems (MASs) facing hybrid cyber-attacks. It enhances consensus protocols and system stability against accumulated attack effects.
Area of Science:
- Control Theory
- Cyber-Physical Systems
- Networked Systems
Background:
- Consensus in multi-agent systems (MASs) is vulnerable to cyber-attacks targeting connectivity and information integrity.
- Fractional-order dynamics exacerbate attack effects due to their hereditary property, complicating stability analysis and protocol design.
- Heterogeneous MASs present unique challenges in achieving robust consensus under adversarial conditions.
Purpose of the Study:
- To investigate heterogeneous fractional-order MASs under hybrid attacks (Denial-of-Service and deception).
- To develop a fractional-order attack-resilient control framework ensuring leader-following consensus.
- To analyze the influence of fractional order on attack tolerance and system performance.
Main Methods:
- Design of a distributed resilient control protocol.
- Integration of fractional-order state observers and attack estimators.
- Derivation of sufficient conditions from a switching perspective, establishing an order-dependent attack tolerance condition.
Main Results:
- A fractional-order attack-resilient control framework was proposed and validated.
- Leader-following consensus with cooperative uniformly ultimately bounded (UUB) was achieved.
- An order-dependent attack tolerance condition was established, highlighting the impact of fractional order.
Conclusions:
- The proposed framework effectively ensures consensus in fractional-order MASs under hybrid attacks.
- The fractional order significantly influences the system's attack tolerance and overall performance.
- The study provides a robust approach for designing resilient control systems in complex networked environments.
Related Concept Videos
Distribution Reliability and Automation
Distribution reliability in electrical power systems is critical for ensuring an uninterrupted power supply to consumers at minimal cost. According to IEEE Standard Terms, reliability is the probability that a device will function without failure over a specified time period or amount of usage. For electric power distribution, this translates to maintaining continuous power supply and addressing customer concerns over power outages. Several indices, as defined by IEEE Standard 1366-2012, are...
Line Protection with Impedance Relays
Coordinating time-delay overcurrent relays in complex radial systems and directional overcurrent relays in multi-source transmission loops can be challenging. Impedance relays address these issues by responding to the voltage-to-current ratio, specifically measuring the apparent impedance of a line. These relays become more sensitive during faults as current increases and voltage decreases, thereby reducing the apparent impedance.
Under normal conditions, low load currents keep the measured...
Under normal conditions, low load currents keep the measured...
Collisions in Multiple Dimensions: Introduction
It is far more common for collisions to occur in two dimensions; that is, the initial velocity vectors are neither parallel nor antiparallel to each other. Let's see what complications arise from this. The first idea is that momentum is a vector. Like all vectors, it can be expressed as a sum of perpendicular components (usually, though not always, an x-component and a y-component, and a z-component if necessary). Thus, when the statement of conservation of momentum is written for a problem,...
Radial System Protection
Radial systems employ time-delay overcurrent relays to reduce load interruptions. When a fault occurs, the nearest breaker opens first, while upstream breakers remain closed due to longer delay settings. This approach ensures minimal disruption to the rest of the system.
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
Zones of Protection
In power systems, the entire setup is divided into protective zones to isolate faults and protect the rest of the network. These zones include generators, transformers, buses, transmission lines, distribution lines, and motors. Each zone can be visualized as a separate room in a house, with each room protected by its own circuit breaker.
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
Masking and Demasking Agents
EDTA titrations may necessitate masking and demasking agents to temporarily protect a particular metal ion in a mixture from the EDTA reaction. These agents facilitate the sequential analysis of the metal ions by forming stable complexes with some—but not all—metal ions during certain steps.
There are many masking agents, such as cyanide, fluoride, triethanolamine, thiourea, and 2,3-bis(sulfanyl)propan-1-ol (formerly 2,3-dimercapto-1-propanol), with the masking agent chosen based on the metal...
There are many masking agents, such as cyanide, fluoride, triethanolamine, thiourea, and 2,3-bis(sulfanyl)propan-1-ol (formerly 2,3-dimercapto-1-propanol), with the masking agent chosen based on the metal...